CCTV UPS Power Supply Edge Span Series

300W DC UPS Industrial POE Switch and Lithium Battery All in One Outdoor UPS System

Application of CCTV UPS Power Supply

CCTV UPS Power Supply is a CCTV outdoor UPS system used in Video Surveillance systems. It provides power to surveillance cameras via POE/POE+/POE++ and also provides complete layer 2 functions, so its first function is to act as a layer 2 POE switch. At the same time, in order to solve the unstable power supply often faced by video surveillance networks, CCTV UPS power supply has built-in high-reliability UPS power supply and lithium battery, so as to ensure that the CCTV camera system can continue to work uninterruptedly in the event of power outages. In addition, Edgeware has designed the system to IP65/NEMA4X level ingress protection for the requirements of outdoor CCTV camera scenarios, so that whether it is used as a UPS pole mounted or wall mounted, it can calmly cope with outdoor use and work stably for a long time.

Contact Us

Features of CCTV UPS Power Supply

Ingress Protection with IP65/NEMA4X

CCTV UPS Power Supply needs to be designed with IP65/NEMA4X level ingress protection. This will ensure that the power supply is protected from dust, water and other environmental factors. In addition to IP65/NEMA4X level protection, CCTV UPS Power Supply should also be designed with surge protection to protect against surges and spikes in power supply. 

Dust Free Design

CCTV outdoor UPS must withstand harsh environmental conditions, such as extreme temperatures, humidity, dust, and even potential physical impacts. A rugged design ensures that the UPS for surveillance system remains reliable and functional, maintaining power to the CCTV cameras even in adverse situations.

POE+(802.3at) POE++(802.3bt)

One important aspect to consider when selecting a CCTV UPS power supply is its ability to support Power over Ethernet (PoE). PoE technology allows for both data and power to be transmitted over a single ethernet cable, eliminating the need for separate power cables. This not only simplifies installation, but also reduces potential points of failure.There are two main types of PoE: PoE+ and PoE++. PoE+ delivers up to 30watts of power per port, while PoE++ can provide up to 110 watts.

Surge Protection

CCTV UPS Power Supply requires a complete lightning protection design to ensure the safety and normal operation of the equipment. This is especially important for outdoor CCTV systems that are exposed to harsh weather conditions.In order to protect CCTV outdoor UPS from lightning strikes, a proper lightning protection design must be implemented. This design should include various components such as surge protectors, grounding systems, and bonding methods.

Remote Monitoring and Management

CCTV UPS power supply deployed in remote areas, and the maintenance cost is extremely high. When the number of sites increases, it will be difficult to know the working status of the sites without a complete remote monitoring and management software platform. When a site has problems, it will cause multiple site maintenance, greatly increasing the maintenance cost of the entire network.

Good Quality Battery For Long Term Operaiton

Good quality battery is very important for outdoor UPS system durable operation , as it can determine the reliability and longevity of the system. It is essential to choose the right type of battery for your outdoor UPS system based on its specific needs and requirements.

Edge Span Series CCTV UPS Power Supply

  • Industrial level 300W DC-UPS
  • Layer 2 8 Ports POE Switch,8*1000 Base-T LAN portswith 2ports 802.3bt 110W, 6 ports 802.3at 30W, 2 ports 1000Base-x or 1000Base-T uplink.
  • High quality lithium battery with 48V10AH 480Wh power that can last whole system 2-4 hours system autonomy
  • Whole system sealed with IP65/NEMA4X ingress protection
  • 20Ka lightning protection for power input , 6Ka for Ethernet ports.

How to Install CCTV UPS Power Supply

Install on Pole as Pole Mouted Outdoor UPS

Edge Span U60 CCTV UPS Power Supply installation can be pole mounted

Install on Wall as Wall Mounted Outdoor UPS

Edge Span U60 CCTV UPS Power Supply installation can be wall mounted

Advantages of Edge Span U60 CCTV UPS Power Supply to Customers

UPS Battery POE Switch All Inlcuded Design

Based on Edgeware’s all-in-one design, our CCTV UPS power supply is an UPS, Battery, POE switch are all included in the system. This provides customers with a one-stop delivery experience and greatly accelerates site delivery time. Customers do not need to use the traditional outdoor cabinet site deployment method to integrate sites, connect cables, and test.

Comprehensive Remote Management

Edge Span U60 CCTV UPS power supply has built-in comprehensive monitoring and management functions, which can monitor and manage the status of POE switch, UPS, battery, and AC input. Therefore, operation and maintenance personnel can easily understand the status of the entire network in the management center.

Complete Lightning Protection and Grounding Design for Outdoor Environments

Edgeware’s rich deployment experience around the world, especially in rainforest areas, gives us rich experience in thunderstorm areas. Therefore, Edge Span CCTV UPS power supply optimizes lightning protection design and grounding design for outdoor deployment, so that the entire system is protected from the impact of lightning in long-term operation, thereby ensuring the reliable long-term operation of the system.

POE+/POE++ to Power Up All Types of Cameras

Our CCTV UPS power supply includes POE+ (802.3at) and POE++ (802.3bt) functions, so that a single system can power the entire CCTV camera system. High-definition cameras and those with advanced features such as PTZ (Pan-Tilt-Zoom) may demand higher power, making POE++ (802.3bt) an essential feature. 

Edge Span U60 All in One CCTV UPS Power SupplySpecifications

Dimension

W*H*D 295mm*355mm*150mm

Weight

12.5kg(with all system)

Material

Aluminum

Ingress Protection

IP65

Heat Dissipation

No fan design, natural heat dissipation

System Operating Temperature

-20~+75°C, 5%~90% RH Non condensing

DC-UPS

Rated Power 300W

Input 110V/220V 50/60Hz Output 42.00-58.00VDC

Battery

48V10AH Lithium Battery with BMS

Surge Suppression

20KA

Protection

Remote control power on and off from Edgeware convergence platform

10A 110v/220v

Leakage Protection

Overvoltage Protection

Under Voltage Protection

Overcurrent Protection

Short circuit Protection

Lightning Protection

Network Module:

GE Downlink: 8*10/100/1000M Base-T ports

GE Uplink : 2 *10/100/1000M Base-X or Base T port

Layer 2 POE switch module manageable

PoE:

6*POE/POE+ Ports with 150W max power 

2*POE++ 802.3bt with 110W

Total power should not be bigger 250W

Output Power

DC12V DC48 can be customized based on requirement

Output and Input Signal

External Sensor Integration can be customized based on requirement

System Monitoring and Management

Work with Edgeware Convergence software platform to perform system monitoring and management

Environment Monitoring

System temperature, humidity.

Box open and close status

UPS Status Monitoring

Input Voltage, Output Voltage

Input/Output Power,Rated Power

Battery Charge/Discharge Current

Input Current, Load Current

Normal, Power Grid Off, Fault

AC Power Input Monitoring

Remote Control

Failure Status

Voltage

Current

Undervoltage

Overvoltage

Overcurrent

Current leakage

Battery Status Monitoring

Battery voltage , current, remaining capacity, temperature

Battery working status, battery charge and discharge current

Battery health estimation( Battery life time estimation )

External Light Control

External light controlt

Typical Application Scenario

cctv cabinet,solar cabinet, solar termination cabinet, Solar Controller enclosure, video surveillance cabinet, IoT Cabinet, IoT device enclosure, IoT enclosures

Smart City, Industrial Control, video surveillance, Telecom

Network Module Switching Capacity

128Gbps

MAC

8K

Network Module Protocol Supported

4K VLAN based on port, IEEE802.1q VLAN based on the protocol, VLAN based on MAC QinQ configuration, Port configuration of Access, Trunk, Hybrid

LACP, Static aggregation, Max 3 aggregation groups and 8 ports per group.

STP (IEEE802.1d),RSTP (IEEE802.1w),MSTP (IEEE802.1s)

MLD Snooping v1/v2,Multicast VLAN IGMP Snooping v1/v2, Max 1024 multicast groups, Fast log out

Bidirectional data mirroring based on port

Flow-based Rate Limiting Flow-based Packet Filtering 8*Output queues of each port 802.1p/DSCP priority mapping Diff-Serv QoS,Priority Mark/Remark Queue Scheduling Algorithm (SP, WRR,)

Port-based Issuing ACL,ACL based on port and VLAN L2 to L4 packet filtering, matching first 80 bytes message. Provide ACL based on MAC, Destination MAC address, IP Source, Destination IP, IP Protocol Type, TCP/UDP Port, TCP/UDP Port Range, and VLAN, etc

IP-MAC-VLAN-Port binding ARP inspection,Anti-DoS attack AAA & RADIUS,MAC learning limit Mac black holes,IP source protection IEEE802.1X & MAC address authentication Broadcast storm control,Backup for host datum

SSH 2.0,SSL,Port isolation,ARP message speed limit User hierarchical management and password protection

DHCP Client,DHCP Snooping,DHCP Server,DHCP Relay

×