UPS for CCTV-Edge Span U30 LSP-3

Layer 2 Industrial POE Switch, 100W Industrial UPS and Battery All in One UPS for CCTV

What is UPS for CCTV

UPS for CCTV is a UPS designed specifically for CCTV camera deployment scenarios. Different from general UPS, UPS for CCTV should focus on the stable operation of UPS in outdoor complex environments. In addition, the power supply for general video surveillance scenarios is based on POE, and POE is used as the main output mode to power CCTV cameras. At the same time, based on the diversity of CCTV camera backhaul networks deployed outdoors, multiple backhaul modes such as 4G/5G, Ethernet, Fiber, and GPON are considered. This makes it not only a power supply device, but also an edge network and power all in one device. Edge Span U30 LSP-3 is a UPS for CCTV designed for 3 cameras or less in CCTV scenarios. As a lightweight IP65 Outdoor UPS, it is based on a 100w mini UPS with indutrial level design, with its own battery inside the shell, and supports one-stop deployment. In addition, CCTV camera scenarios are often part of smart city projects. Edge Span U30 LSP-3 can also provide DC12V/DC24V and RS485 integrated interfaces for IoT sensors according to customer needs.

Contact Us

Features of UPS for CCTV

Lightweight IP65/NEMA4X

The scenario of 1-3 cameras requires CCTV UPS with lightweight and fast deployment. However, we cannot ignore the environmental challenges faced by CCTV UPS when it is deployed outdoors. For example, various rural areas, rainforests, seaside, high humidity environments, etc. pose challenges to the ongoing system. Therefore, the UPS for CCTV designed by Edgeware are all IP65/NEMA4X or above.

Rugged and Durable Design

CCTV UPS needs to operate outdoors for many years, exposed to wind, rain and even typhoons. The other shells must be strong and durable so that the whole system can operate in outdoor environment for a long time. So we designed the shell of the whole system to be rugged and durable to meet this challenge.

No Rust

Rust is a serious challenge for CCTV UPS. CCTV UPS needs to run outdoors for a long time. If there is a problem with the material process of the whole system, it will cause rust. The problem of rust affects not only the appearance but also causes water seepage over time, damaging the shell and the internal equipment. We attach great importance to the rust-free design of the whole machine. The whole shell is an integrated cast aluminum shell, which fundamentally avoids the possibility of rust.

Surge Protection

Another major challenge in the outdoor environment is surge protection. UPS for CCTV requires a comprehensive design and consideration of the lightning protection and grounding of the entire system. For power input and power output, lightning protection of 20Ka level or above is required. For other signal interfaces, such as Ethernet port and signal port, lightning protection is also required. This allows the entire system to work stably and long-term outdoors.

Whole Sytem Natural Heat Dissipation

Traditional UPS generally uses fans for heat dissipation. Traditional CCTV UPS uses fans to dissipate heat by placing the UPS in an outdoor power cabinet. However, this is not a good idea because the fan itself is a mechanical structure and will inevitably be damaged with a certain probability during long-term operation, thus requiring on-site replacement. However, CCTV UPS is usually deployed outdoors. The on-site maintenance and replacement costs for scenarios such as on wall, on pole, or in rural areas are very high. In areas with high labor costs, the OPEX of the entire network will inevitably be too high. Therefore, we believe that natural heat dissipation of the entire system is the most suitable heat dissipation method for CCTV UPS.

POE+/POE++

The best power supply for video surveillance cameras is POE, which fully guarantees the reliability of the system and reduces the complexity of the networking. Outdoor UPS for CCTV must include POE+ (802.3at) and POE++ (802.3bt) functions, so that a single system can power the entire CCTV camera system. High-definition cameras and those with advanced features such as PTZ (Pan-Tilt-Zoom) may demand higher power, making POE++ (802.3bt) an essential feature. 

Edge Span U30 LSP-3 UPS for CCTV

  • 100w mini UPS with indutrial level design
  • Industrial level manageable layer 2 POE Switch(3 ports downlink with 1ports 802.3bt 60W, 2 ports 802.3at 30W, 1 ports uplink can be configured 1000Base-x or 1000Base-T) Total POE power is 90W.
  • Lithium battery 5AH(48V)with 240Wh power that can support the whole system to run for 2 hours – 4 hours without power grid
  • Totally sealed design reaches IP65/NEMA4X ingress protection,dust and water penetration-free system
  • Optional configuration with comprehensive system monitoring for in enclosure environment, AC input voltage current power, battery management, UPS management, POE switch management.
  • 20Ka surge protection

Dimension and Weight

Edge Span U30 LSP-3 UPS for CCTV optimizes the weight and volume of the UPS to accommodate 1-3 CCTV cameras, making it possible for a single engineer to carry it, greatly simplifying on-site installation:

  • The weight of the whole system is 8.5kg (with battery installed)
  • Dimension of the whole system: 231mm*321mm*135mm (W*H*D)

Installation of UPS for CCTV

Pole Mounting Installation

Edge Span U30 UPS for CCTV can support pole mounting installation

Wall Mounting Installation

Edge Span U30 UPS for CCTV can support wall mounting installation

Application of UPS for CCTV

Edge Span U30 LSP-3 UPS for CCTV can be applied in the following two aspects:

(1) Video surveillance scenario, connecting 1-3 CCTV cameras. The whole system has 1 802.3bt, which supports a maximum of 60W. There are also 2 802.3at channels, which support a maximum of 30W. The POE power of the whole machine is 90W. Because the Edge Span U30 has one 100w mini UPS embedded so just enough to meet the needs of the scenario without paying extra costs for unnecessary capacity.The POE switch board of Edge Span U30 also has complete layer 2 features and can be used as a camera aggregation node.

(2) IoT sensor access scenario, connecting 2 IoT sensors. Provide power and sensor integration for IoT sensors. Our UPS for CCTV has edge control and programmability, which can integrate IoT data reading into the Edgeware software platform. It can also organize the data into MQTT format and send it to the customer’s software platform.

Port Configuration

The above picture shows the port configuration of UPS for CCTV Edge Span U30 LSP-3. The whole machine has three LAN ports 1000Base-T, one of which is 802.3bt 60W, and the other two are 802.3at 30W.

The whole machine connects to two sensors through the IoT sensor port, which can provide DC12V or DC24Vpower and RS485. This port is not configured by default and is configured according to the needs of the customer scenario.

The Uplink port can be configured as 1000Base-X or 1000Base-T

Main Function Units

As shown in the figure above, this is the configuration of UPS for CCTV Edge Span U30 LSP-3

IoT Sensor Integration

Edgeware believes that UPS for CCTV is not just a power node. Its location in the entire network makes it a natural edge node, responsible for connecting to various devices. CCTV cameras and IoT sensors often appear in edge networks in smart city projects. Therefore, if UPS for CCTV is an edge control device, it can provide power for these devices while also serving as an edge network aggregation and sensor edge control node, providing edge computing and IoT sensor integration. Edge Span U30-LSP is developed based on this design concept. Edgeware can provide customers with a full set of sensors to meet the needs of various project scenarios, and we can also customize and develop integrated customer sensors.

UPS Remote Monitoring and Management

As the core component of UPS for CCTV, remote monitoring and early warning of UPS working status are very important. Edge Span 360 LSP-3 has a built-in core edge control unit, which can monitor the UPS status such as input voltage, input current, operating power, UPS temperature, PFC voltage, output voltage, output current, battery voltage, battery current, output power and other important operating parameters, and reflect them to the software platform, so that customers can monitor UPS operation in real time and view historical operating status.

Battery Management System

The life and operation of the battery are also very important for the operation of the UPS for CCTV, especially when there are a large number of sites and power outages are very frequent. After 5-10 years of site deployment, it is inevitable that some batteries will need to be replaced because they have exceeded the usage limit. At this time, if there is a battery management system in the UPS for CCTV, its status can be remotely monitored to understand the number of charge and discharge cycles to determine the maintenance plan. The built-in BMS of Edge Span U30 can provide you with various information such as battery voltage, current, power, power, number of cycles, single cell voltage, cell voltage balance, etc. to help you understand its operation status through our software platform at the maintenance center.

Envrionment Management

The deployment environment of UPS for CCTV power supply is relatively complex, so Edge Span has built-in temperature and humidity sensors that can synchronize real-time conditions to the software platform.

POE Switch Management and Control

The POE switch board embedded in the system will be managed by our software platform. The port status can be remotely managed through the software platform. The POE port can be remotely controlled to shut down and restart. Based on this function, the CCTV camera can be restarted remotely to solve the camera freeze problem in most cases.

Third Party Software Platform Integration

Although Edgeware has its own software platform, customers often have their own considerations for the management of the entire network and have their own management system or OSS. UPS system is only part of customer network.Therefore, Edge Span can also provide services that are integrated into your third-party platform.

PRTG Software Platform

https://www.paessler.com/

Thingsboard Software Platform

https://thingsboard.io/

Customers have various ways of managing UPS for CCTV cameras, so we also provide MQTT and SNMP protocols to connect with customers’ software platforms.

MQTT Inteface Report

SNMP Interface Report

Customization Development

We also provide customers with customized development based on Edge Span U30 UPS for CCTV, which includes the following services:
(1) Embed the customer’s equipment in Edge Span U30 enclosure, such as replacing the POE switch board with the customer’s POE switch. Because Edge Span U30 enclosure is relatively small, so we need to check carefully with you case by case
(2) Decrease the battery capacity
(3) Customize the control logic of the whole machine. For example:
A. When the battery capacity is less than 40%, close several specific POE ports to put the whole system into power saving mode.
Read a specific sensor, set an alarm, and turn on a certain device.
B. The above are just simple examples, because our company has customized and developed many projects and it is impossible to list them one by one. In short, we are very willing to carry out customized development based on customer scenarios to achieve one-stop delivery.

Specifications

Edge Span U30 LSP-3 All in One UPS for CCTV Specifications

Dimension

W*H*D 231mm*321mm*135mm

Weight

8.5kg(with all system)

Material

Aluminum

Ingress Protection

IP65

Heat Dissipation

No fan design, natural heat dissipation

System Operating Temperature

-20~+75°C, 5%~90% RH Non condensing

DC-UPS

Rated Power 100W mini UPS

Input 110V/220V 50/60Hz Output 42.00-58.00VDC

Battery

48V5AH Lithium Battery with BMS

Surge Suppression

20KA

Protection

Remote control power on and off from Edgeware convergence platform

10A 110v/220v

Leakage Protection

Overvoltage Protection

Under Voltage Protection

Overcurrent Protection

Short circuit Protection

Lightning Protection

Network Module:

GE Downlink: 3*10/100/1000M Base-T ports

GE Uplink : 1 *10/100/1000M Base-X or Base T port

Layer 2 POE switch module manageable

PoE:

2*POE/POE+ Ports with 802.3at 30W max power 

1*POE++ 802.3bt with 60W

Total power should not be bigger 90W

Output Power

DC12V DC24V DC48 can be customized based on requirement

Output and Input Signal

External Sensor Integration can be customized based on requirement

System Monitoring and Management

Work with Edgeware Convergence software platform to perform system monitoring and management

Environment Monitoring

System temperature, humidity.

Box open and close status

UPS Status Monitoring

Input Voltage, Output Voltage

Input/Output Power,Rated Power

Battery Charge/Discharge Current

Input Current, Load Current

Normal, Power Grid Off, Fault

AC Power Input Monitoring

Remote Control

Failure Status

Voltage

Current

Undervoltage

Overvoltage

Overcurrent

Current leakage

Battery Status Monitoring

Battery voltage , current, remaining capacity, temperature

Battery working status, battery charge and discharge current

Battery health estimation( Battery life time estimation )

External Light Control

External light controlt

Typical Application Scenario

cctv cabinet,solar cabinet, solar termination cabinet, Solar Controller enclosure, video surveillance cabinet, IoT Cabinet, IoT device enclosure, IoT enclosures

Smart City, Industrial Control, video surveillance, Telecom

Network Module Switching Capacity

128Gbps

MAC

8K

Network Module Protocol Supported

4K VLAN based on port, IEEE802.1q VLAN based on the protocol, VLAN based on MAC QinQ configuration, Port configuration of Access, Trunk, Hybrid

LACP, Static aggregation, Max 3 aggregation groups and 8 ports per group.

STP (IEEE802.1d),RSTP (IEEE802.1w),MSTP (IEEE802.1s)

MLD Snooping v1/v2,Multicast VLAN IGMP Snooping v1/v2, Max 1024 multicast groups, Fast log out

Bidirectional data mirroring based on port

Flow-based Rate Limiting Flow-based Packet Filtering 8*Output queues of each port 802.1p/DSCP priority mapping Diff-Serv QoS,Priority Mark/Remark Queue Scheduling Algorithm (SP, WRR,)

Port-based Issuing ACL,ACL based on port and VLAN L2 to L4 packet filtering, matching first 80 bytes message. Provide ACL based on MAC, Destination MAC address, IP Source, Destination IP, IP Protocol Type, TCP/UDP Port, TCP/UDP Port Range, and VLAN, etc

IP-MAC-VLAN-Port binding ARP inspection,Anti-DoS attack AAA & RADIUS,MAC learning limit Mac black holes,IP source protection IEEE802.1X & MAC address authentication Broadcast storm control,Backup for host datum

SSH 2.0,SSL,Port isolation,ARP message speed limit User hierarchical management and password protection

DHCP Client,DHCP Snooping,DHCP Server,DHCP Relay

×