UPS for Starlink with POE and IoT Router-Edge Span U1000AD-ST
1000VA AC/DC Dual Power UPS, Lithium Battery, Starlink POE, Normal POE, IoT Router All in One System
Edge Span U1000AD-ST UPS for Starlink
Edge Span U1000AD-ST UPS for Starlink is a multifunctional smart node designed specifically for Starlink scenarios. Starlink scenarios are often located in remote areas, where the environment is relatively complex and the power supply is often unstable. Starlink often has various network devices hanging down, and their power consumption standards are different. Some use AC power, some use DC power, and some use POE. Edge Span U1000AD-ST provides 1000VA AC power for Starlink scenarios, as well as 400W DC48V power. In addition, it provides 802.3at and 802.3bt POE interfaces for network devices. Finally, it also provides corresponding POE power supply for Starlink. This simplifies the deployment of the entire scenario.
In addition, in view of the complex environment of Starlink deployment in remote areas, Edge Span U1000AD-ST is designed with IP65 ingress protection.
Edge Span U1000 UPS for Starlink has an embedded IoT router, which can integrate different external sensors such as weather stations, environmental sensors and other devices according to customer requirements, and process the data at the edge and upload it to the software platform.
In short, with the deployment of Edge Span U1000AD-ST, the network, power supply and control of Starlink deployment will be greatly simplified, making the deployment of Starlink’s overall solution fast and integrated.
Product Video
Weakness of Traditional Starlink UPS Scenario
Although Starlink deployment in remote areas solves the problem of backhaul network, applications in various scenarios need to be built by customers themselves. For example, CCTV cameras provide security monitoring, WIFI APs provide network coverage, and some IoT sensor monitoring data is backhauled. The figure above shows a typical Starlink application scenario, which uses traditional UPS, POE switches, and IoT routers. Although this achieves the goal, it has the following weaknesses:
Complex power supply and network topology
When we build the whole solution in the traditional way, the power and network topology are too complicated. It should be noted that since Starlink sites have no network, they are generally located in relatively remote areas. Building a relatively complex solution in a remote area is very uneconomical from the perspective of maintenance and installation.
The variety of equipment makes transportation to the site expensive
As we can see, there are many types of equipment in traditional solutions. As we mentioned before, Starlink sites are generally located in remote areas. Therefore, it is not easy to transport these devices to the site. And if the power backup time is long, the lead-acid battery will be very heavy, which greatly increases the transportation cost.
Site construction and commissioning costs are high
The cost of construction and debugging based on such a topology will be very high. It is conceivable that engineers with certain skills will be required to go to the site for installation and debugging. However, because the site is remote, the time spent by the engineers on the road plus the debugging period will make the total cost very high.
High cost of monitoring and maintenance
It can be found that it is difficult to monitor all devices when building the entire solution with this traditional topology. It is also not easy to find a software platform to monitor all devices. Because the site is located in a remote area, if the device is not monitored and managed by the software, then when the entire solution fails, it is difficult to know what happened. In this way, engineers have to be sent to the remote site to locate the problem, which greatly increases maintenance costs.
All in One UPS for Starlink Solution
Compared with the traditional UPS for starlink, Edgeware provides an all-in-one solution. We believe that UPS is a smart node aggregation node. Through Edgeware’s Edge Span series all-in-one smart node technology, we integrate UPS, POE, IoT router, lithium battery, edge computing and other technologies into an IP65 enclosure. This system has the following main features:
Starlink POE
System is equipped with a Starlink-specific POE port, which simplifies the Starlink cable from a complex configuration of AC cable plus Ethernet cable to a single Ethernet cable that provides both power and network signals.
802.3at POE+ and 802.3bt POE++
The all in one Starlink UPS can be configured with POE+ and POE++, which can provide energy for all types of POE devices such as CCTV camera, WIFI AP, etc.
DC12V/DC24V and Modbus
The all in one Starlink UPS can be configured with DC12V/DC24V and modbus according to customer needs so that external IoT sensors can be integrated.
UPS with AC110V/220V and DC48V Dual Voltage Output
High Power Density Lithium Battery
The all in one Starlink UPS can configure lithium batteries of different capacities according to the customer’s load and system autonomy time to meet customer requirements. At the same time, due to the higher power density of lithium batteries compared to lead-acid batteries, the batteries are lighter and smaller in size, thus simplifying the process of transporting equipment to the station.
IoT Router with Edge Control and Computing
The all in one Starlink UPS has an embedded IoT router with edge control and computing capability, which makes it easy to effectively monitor and manage the entire system while integrating and processing data from IoT sensors.
Cloud Management Software Platform
The system can be managed and monitored through Edgeware’s Convergence Software platform, and data from various IoT sensors can be integrated for data visualization. If necessary, we can also report data to a third-party management software platform through all in one UPS for Starlink.
Features of Edge Span U1000AD-ST UPS for Starlink
Starlink POE Function Embedded
Designed for Starlink scenarios, it is specially embedded with Starlink-specific POE function to simplify the installation and debugging of Starlink.
AC and DC48V Dual Power UPS
The system’s built-in UPS fully considers the power requirements of peripheral devices in the Starlink scenario, providing the voltage required by the DC48V communication power supply standard and AC voltage. If the customer needs it, you can also add commonly used voltages such as DC12V and DC24V.
IP65/NEMA 4
The system fully considers the possible deployment scenarios of Starlink, both outdoor and indoor. Aiming at the complex natural environment in remote areas, the system is designed with IP65-level ingress protection, thus fully ensuring the stable operation of the entire system without being affected by the complex external environment.
Outdoor Optimized Rugged Design
System embedded in a cast aluminum shell that has an IK08 protection rating which is optimized for outdoor deployment.
No Rust for Long Term Operation
With a rust-proof design, system ensures that the entire system is completely free of rust and can operate stably for a long time.The whole system is well adapted to Starlink’s deployment environment, both indoors and outdoors.
Surge Protection
System with comprehensive lightning protection design which is dedicated to outdoor environment.
FAN Less Dissipation
The system is designed as an overall fanless design, and the heat dissipation is based on the natural heat dissipation of the entire machine shell, which is well adapted to the requirements of Starlink at remote sites. The lack of mechanical parts such as fans in the device can better meet the requirements of long-term operation of the device without maintenance.
Customized Battery Capacity
The battery capacity is designed entirely based on the customer’s load and system autonomy time, and the battery is minimized and lightweight to simplify transportation to remote sites, reducing transportation and installation costs.
POE+/POE++Functions
The system has PoE+ Ports Can also add one PoE++ 802.3bt port which can reach 110W. It can be adapted to most POE devices, thus simplifying the installation of customer equipment in Starlink scenarios.
IoT Sensor Control Interface
System supports 2 RS485, 1 RS232, 1 DI, and 1 DO. Modbus can be run on RS485. Therefore, customers can build their edge control site with control devices functions such as battery BMS, solar controller, IoT Sensors, etc. If customer request more interfaces, we can add based on customer request.
IoT Edge Computing and Control
The system can configure edge computing and control core to manage and calculate edge IoT and other devices, and transmit these data back to the server software platform with Starlink, so as to extend IoT to remote areas that are difficult to reach through various networks. At the same time, edge computing and control core can also use its own protocol capabilities to connect the site
WIFI Supported
System has 802.11n WIFI function as optional . It can provide small amount of WIFI access for users in edge network scenarios. It can also facilitate engineers to access WIFI for configuration and maintenance.
Edge Span U1000AD-ST UPS for Starlink Main Specification
- Industrial level 1000VA UPS with AC110/220V output 1000VA, DC48V output 400W.
- 1 port Starlink POE port to power Starlink antenna as well as working as WAN port of the whole system.
- Starlink POE has 120W, 200W, 320W options.
- 4*802.3at(PoE+) ports , can configure one port as 802.3bt PoE 110W. ( Can expand to 8 ports POE+ as customer request)
- IoT Router with 4*1000Base-T LAN ports and 1*1000Base-T/1000Base-X combo WAN port
- Edge computing module to control the whole system with UPS, Battery and in enclosure environment. Also can use RS485 RS232 DI DO to integrate IoT sensors thrid party.
- Lithium battery 20AH(48V)with 960Wh power that can support the whole system to run for 2 hours – 4 hours without power grid. Can reduce or increase the battery capacity based on customer request.
- Totally sealed design reaches IP65/NEMA 4 ingress protection,dust and water penetration-free system
- Configured with comprehensive system monitoring for in enclosure environment, AC input voltage current power, battery management, UPS management, POE management.
- 20Ka surge protection
- 4G module CAT1/CAT4/CAT6/CAT12 can be embedded, GPS and WIFI function as optional.
Dimension and Weight
Edge Span U1000AD-ST Starlink UPS system’s dimension and weight as followings:
- The weight of the whole system is 24kg (with battery installed)
- Dimension of the whole system: 371mm*450mm*234mm (W*H*D)
Installation of Edge Span U1000AD-ST Starlink UPS
Pole Mounting Installation
Edge Span U1000AD-ST UPS for Starlink supports pole mounting installation
Wall Mounting Installation
Edge Span U1000AD-ST UPS for Starlink supports wall mounting installation
Application of Edge Span U1000AD-ST UPS for Starlink
The figure above shows a typical application of Edge Span U1000AD-ST UPS for Starlink. Starlink can be used to extend the network to areas that were not so easy to cover before. Then, all services of the site are integrated into the smart node of Edge Span, thereby simplifying the complex service connections of the site and greatly accelerating the deployment of customers. Edge Span U1000AD-ST is the core of power, the aggregation node of the entire network, and the core of control and management. Thus, one-stop deployment is achieved.
POE for Starlink
Edge Span U1000AD-ST UPS for Starlink is configured with POE port for Starlink by default, which simplifies the installation and connection of customer Starlink antenna. According to different customer usage scenarios and different power requirements of Starlink, we provide three different levels of Starlink POE configurations: 120W, 200W, and 320W.
Complete Voltage Options for Starlink Whole Scenario
Edge Span U1000AD-ST UPS for Starlink takes into account the power requirements in various scenarios of Starlink. It provides AC power for general equipment and DC48V for Telecom equipment. At the same time, it can be configured with power such as DC12V and DC24V according to customer requirements.
IoT Sensor Edge Control and Computing
Edge Span U1000AD-ST can be used as an integrator for various IoT sensors or control systems in edge networks due to its all-in-one features and node-red support. Combined with Edgeware’s convergence software platform, IoT edge network one-stop delivery can be easily achieved.
Main Steam VPN Supported for Enhanced Security
Edge Span U1000AD-ST Starlink UPS supports mainstream VPN technology, making IP address planning for edge deployment clearer and easier, and also enables direct login for edge site management, making management more convenient. More importantly, it protects data security.
UPS Remote Monitoring and Management
The UPS system is the core component of the Edge Span U1000AD-ST Starlink UPS. Its stable operation is crucial to the entire system. The UPS operating status, input and output parameters, and various alarm conditions can be monitored and managed. This allows maintenance personnel to know the working status of the UPS system remotely by monitoring the operating parameters.
Battery Management System
The life and operation of the battery are also very important for the operation of Edge Span U1000AD-ST Starlink UPS, especially when there are a large number of sites and power outages are very frequent. After 5-10 years of site deployment, it is inevitable that some batteries will need to be replaced because they have exceeded the usage limit. At this time, if there is a battery management system in the Edge Span U60-LTEP, its status can be remotely monitored to understand the number of charge and discharge cycles to determine the maintenance plan. The built-in BMS of Edge Span can provide you with various information such as battery voltage, current, power, power, number of cycles, single cell voltage, cell voltage balance, etc. to help you understand its operation status through our software platform at the maintenance center.
Envrionment Management
The deployment environment of Edge Span U1000AD-ST Starlink UPS is relatively complex, so Edge Span has built-in temperature and humidity sensors that can synchronize real-time conditions to the software platform.
POE Management and Control
CCTV cameras and WIFI ap devices sometimes freeze, and the solution usually requires restarting these devices. However, because Starlink is often deployed in remote sites, it is not easy to restart these POE devices at the site. To address this problem, the POE port in the Edge Span U1000AD-ST UPS for Starlink can be remotely restarted through the Edgeware software platform, helping customers solve the problem without having to go to the site.
Third Party Software Platform Integration
Although Edgeware has its own software platform, customers often have their own considerations for the management of the entire network and have their own management system or OSS. POE UPS is only part of customer network.Therefore, Edge Span can also provide services that are integrated into your third-party platform.
Specifications
Edge Span U1000AD-ST UPS for Starlink Specifications | |
Dimension | W*H*D 371mm*450mm*234mm |
Weight | 24kg(with all system) |
Material | Aluminum |
Ingress Protection | IP65 |
Heat Dissipation | No fan design, natural heat dissipation |
System Operating Temperature | -20~+75°C, 5%~90% RH Non condensing |
DC-UPS | Rated Power 1000W Input 110V/220V 50/60Hz Output 42.00-58.00VDC and AC110V or 220V( AC Voltage need to define based on customer’s country and region ) |
Battery | 48V20AH Lithium Battery with BMS(960Wh) |
Surge Suppression | 20KA |
Protection | Remote control power on and off from Edgeware convergence platform 20A 110v/220v Leakage Protection Overvoltage Protection Under Voltage Protection Overcurrent Protection Short circuit Protection Lightning Protection |
Starlink POE | 120W, 200W,320W based on customer scenario to configure With SPD embedded. |
Network Module: | IoT Router Module GE Downlink: 4*10/100/1000M Base-T ports GE Uplink : 1*10/100/1000M Base-X or Base T ports |
PoE: | 4*POE/POE+ Ports with 30W max power per port 1*POE++ Ports with 110W max power per port (Optional ) Total power should not be bigger 400W POE ports can be customized to be 8 based on customer request |
Output Power | AC110V/220V DC48. DC12V,DC24V can be customized based on requirement AC power can be 1000VA, DC48V Max 400W |
Output and Input Signal | RS485(Modbus), RS232, DI, DO can be configured based on customer reqquest |
System Monitoring and Management | Work with Edgeware Convergence software platform to perform system monitoring and management |
Environment Monitoring | System temperature, humidity. |
UPS Status Monitoring | Input Voltage, Output Voltage Input/Output Power,Rated Power Battery Charge/Discharge Current Input Current, Load Current Normal, Power Grid Off, Fault |
AC Power Input Monitoring | Remote Control Failure Status Voltage Current Undervoltage Overvoltage Overcurrent Current leakage |
Battery Status Monitoring | Battery voltage , current, remaining capacity, temperature Battery working status, battery charge and discharge current Battery health estimation( Battery life time estimation ) |
Typical Application Scenario | Starlink Site |
WIFI(Optional) | |
WIFI Mode | IEEE 802.11b/g/n/ac, Access Point (AP), Station (STA) |
WiFi Security | WPA2-Enterprise – PEAP, WPA2-PSK, WEP, WPA-EAP, WPA-PSK; AES-CCMP, TKIP, Auto Cipher modes, client separation |
SSID | SSID hidden mode,dual SSIDs. |
Network Protocol | |
Routing | Static routing, Dynamic routing (BGP, OSPF v2, RIP v1/v2, RIPng) |
Network protocols | TCP, UDP, IPv4, IPv6, ICMP, NTP, DNS, HTTP, HTTPS, FTP, SMTP, SSL v3, TLS, ARP, VRRP, PPP, PPPoE, UPnP, SSH, DHCP, Telnet client, SNMP, MQTT, Wake On Lan (WOL) |
Connection Monitoring | TCP-Ping Reboot, Periodic Reboot, LCP and ICMP for link inspection |
DHCP | Static and dynamic IP allocation, DHCP Relay |
Network Backup | WAN and Mobile back up, can be one as main one as backup. |
VPN | |
OpenVPN | Multiple clients and server can be running simultaneously, 12 encryption methods |
OpenVPN Encryption | DES-CBC, RC2-CBC, DES-EDE-CBC, DES-EDE3-CBC, DESX-CBC, BF-CBC, RC2-40-CBC, CAST5-CBC, RC2-64-CBC, AES-128-CBC, AES-192-CBC, AES-256-CBC |
IPsec | IKEv1, IKEv2, supports up to 4 x VPN IPsec tunnels (instances), with 5 encryption methods (DES, 3DES, AES128, AES192, AES256) |
GRE | GRE tunnel |
PPTP, L2TP | Client/Server services can run simultaneously |
Management | |
SSH | SSH (v1, v2) |
SNMP | SNMP (v1, v2, v3), SNMP trap |
MQTT | MQTT |
GPS | |
GPS | GPS Ooptional |