CCTV Backup Power Supply-Edge Span U1000-LTEP

1000W AC/DC Dual Power UPS,LTE, POE Switch,Battery All in One System Designed for Smart Traffic

CCTV Backup Power Supply-Edge Span U1000-LTEP

Edge Span U1000-LTEP is a customized CCTV Backup Power Supply designed specifically for smart traffic scenario as a POE UPS meanwhile with CAT12 LTE and Inverter Functions. This CCTV backup power supply is mainly deployed in crossroads to provide POE backup power for CCTV cameras, and also provides AC backup power supply for traffic light controller equipment. In some scenarios, there may be communication equipment such as 4G small cells, for which Edge Span U1000-LTEP provides DC48V backup power supply. In addition to the power backup function, Edge Span U1000-LTEP has a built-in PoE Switch that can provide POE+ (802.3at) and POE++ (802.3bt) POE power, and also has a built-in CAT12 LTE Router module. Customers can choose a fiber optic uplink interface or a CAT12 LTE backhaul (there is also a 5G version) based on the backhaul conditions of the smart traffic scenario.

Contact Us

Please note that Edge Span U1000-LTEP is a customized version for smart transportation scenarios in several specific countries in Latin America. If you only need a POE UPS based on Layer 2 POE Switch, please click the following link to enter

If you need POE UPS based on Layer 3 POE router 4G/5G, please click the following link:
    

Product Video

One CCTV Backup Power Supply Site for Smart Traffic Scenario

The left picture shows a site in Latin America and the Caribbean. You can see that CCTV Backup Power Suppy will encounter the following challenges when deployed in such an environment:

(1) The outdoor environment is subject to strong sunlight and rain, which is quite complex.

(2) The site is not far from the sea, so you can imagine that the air humidity is very high.

(3) The electromagnetic radiation around the site is quite complex. There is also a 4G small cell outside the photo.

(4) Thunderstorms are frequent in this area, especially typhoons and storms every summer.

(5) Once installed, the equipment will work for 5-10 years without maintenance. At this time, the system itself needs to have strong reliability.

Features of CCTV Backup Power Supply Edge Span U100 LTEP

Ingress Protection with IP65/NEMA4X

As we have introduced in the previous chapter photos, the deployment environment of CCTV backup power supply is relatively complex. Especially sometimes it is deployed in a seaside environment. If the traditional IP55-level outdoor cabinet is used to build the UPS for CCTV camera system, it will not be able to operate stably for a long time in these harsh environments. Therefore, Edgeware insists on designing the UPS for CCTV camera with IP65/NEMA4X ingress protection to ensure that the system can still operate stably in different challenging environments.

Enclosure with Rugged Design

 

The entire system is ruggedly designed, and the shell reaches IK08 level protection, thus protecting the system inside the shell from external impact.

Rust-Proof

When CCTV backup power supply is deployed in a high humidity and rainy environment, the rusting problem will not only affect the appearance of the equipment, but in many cases it can even corrode the entire system. Therefore, Edgeware insists that a reliable UPS for CCTV should be Rust-free. Edgeware’s product shell is formed by a cast aluminum shell in one step, and aluminum is naturally rust-proof, thus solving the rusting problem.

Surge Protection

Another major challenge in the outdoor environment is surge protection. UPS for CCTV camera requires a comprehensive design and consideration of the lightning protection and grounding of the entire system. For power input and power output, lightning protection of 20Ka level or above is required. For other signal interfaces, such as Ethernet port and signal port, lightning protection is also required. This allows the entire system to work stably and long-term outdoors.

All Components Natural Heat Dissipation

Edgeware’s Edge Span series products are all based on the cooling design of natural heat dissipation, so do Edge Span U1000 LTEP . We believe that the natural heat dissipation feature is different from the cooling design of general FANs. The whole system does not have the limitation of the FAN mechanical part, so that the whole system can be maintained and operated for ten years. This greatly saves the cost of engineers visiting the site for maintenance and directly saves OPEX. 

High Temperature Resistant Long Life Battery

The most vulnerable and core component of the UPS system is the battery. The lithium batteries we use can withstand the relatively high temperature inside the UPS. At the same time, they have a higher energy density than ordinary lead-acid batteries, thus miniaturizing the entire product.

POE+/POE++

As a POE UPS, Edge Span U1000 LTEP CCTV backup power supply supports POE+ (802.3at) and POE++ (802.3bt) functions, a single system can support different types of bullet and PTZ cameras.

Remote Monitoring and Management

All key components of the Edge Span U1000 LTEP system are monitored and managed. Key information can be reported to the Edgeware software platform or to a third-party software platform by MQTT.

AC/DC Dual Output

Edge Span U1000 LTEP CCTV backup power supply supports AC110V or 220V and DC48V. Because the system provides DC and AC dual power supplies, it can provide different voltages for external devices and adapt to the common voltage of Telecom and the AC voltage used by general electrical appliances.

4G CAT12 Uplink

Edge Span U1000 LTEP CCTV backup power supply supports CAT12 high-speed LTE backhaul. In some places where there is no optical fiber, 4G backhaul can be relied on.

Edge Span U1000 LTEP Main Functions

  • Industrial level 1000W AC/DC UPS,dual voltage AC/DC48V output 
  • Industrial level layer3 CAT12 LTE Router(3 ports 1000Base-T downlink, 1 port 1000Base-X uplink can be configured 1000Base-x or 1000Base-T)
  • Industrial level layer2 POE Switch ( 8 ports 1000Base-T downlink, with 2 ports 802.3bt 110W,  6 ports 802.3at 30W, 2 ports 1000Base-X uplink
  • Programable Edge Control Core for system IoT sensor integration and customization control logic
  • Lithium battery 25AH(48V)with 1200Wh power that can support the whole system to run for 2 hours without power grid
  • Totally sealed design reaches IP65/NEMA4X ingress protection,dust and water penetration-free system
  • Configured with comprehensive system monitoring for in enclosure environment, AC input voltage current power, battery management, UPS management, POE switch management.
  • 20Ka surge protection
  • 4G CAT12 module embedded, GPS function available.

Dimension and Weight

Edge Span U1000 LTEP CCTV backup power supply system’s dimension and weight as followings:

  • The weight of the whole system is 24kg (with battery installed)
  • Dimension of the whole system: 371mm*450mm*234mm (W*H*D)

Installation of the System

Pole Mounting Installation

Edge Span U1000 LTEP support pole mounting installation

Wall Mounting Installation

Edge Span U1000 LTEP support wall mounting installation

Application of Edge Span U1000-LTEP CCTV Backup Power Supply Application

CCTV Camera Backup Power Supply and Backhaul

Edge Span U1000-LTEP can provide backup power supply for up to 8 CCTV cameras by POE+ or POE++

Traffic Controller Backup Power Supply

AC power based on Edge Span U1000 LTEP can provide backup power for the traffic controller.

4G Small Cell Backup Power Supply

he DC48V provided by Edge Span U1000-LTEP provides battery backup power supply for Telecom equipment such as 4G small cells.

Main Function Units

As shown in the figure above, this is the configuration of Edge Span U1000-LTEP CCTV Backup Power Supply.

Main Uplink and Backup Uplink Backup Eachother

Edge Span U1000 LTEP CCTV backup power supply supports Ethernet fiber uplink and 4G/5G. In actual operation, they can serve as the main and backup links for each other. For example, the usual deployment method is Ethernet Fiber as the main uplink and 4G/5G as the backup link. When the system detects that the main link is down, it switches to the backup link. When the main uplink is restored, the traffic switches back to the main uplink. This greatly enhances the availability of the entire network.

Main Steam VPN Supported for Enhanced Security

Edge Span U1000 LTEP CCTV backup power supply is designed for smart traffic, and the security of its network is very important. Mainstream VPN technologies such as IPSEC VPN, L2TP VPN, GRE, etc. are already supported. In addition, in actual deployment, the IP address for 4G/5G uplink is allocated by the operator, which will affect the accessibility of the entire network equipment maintenance. After deploying VPN, it is very convenient to plan the IP address of the entire network.

UPS Remote Monitoring and Management

As the core component of Edge Span U1000 LTEP CCTV backup power supply, remote monitoring and early warning of UPS working status are very important. Edge Span U1000 LTEP has a built-in core edge control unit, which can monitor the UPS status such as input voltage, input current, operating power, UPS temperature, PFC voltage, output voltage, output current, battery voltage, battery current, output power, and other important operating parameters, and reflect them to the software platform so that customers can monitor UPS operation in real-time and view historical operating status.

Battery Management System

The life and operation of the battery are also very important for the operation of the UPS for CCTV system, especially when there are a large number of sites and power outages are very frequent. After 5-10 years of site deployment, it is inevitable that some batteries will need to be replaced because they have exceeded the usage limit. At this time, if there is a battery management system in the UPS for CCTV camera, its status can be remotely monitored to understand the number of charge and discharge cycles to determine the maintenance plan. The built-in BMS of Edge Span U1000 LTEP can provide you with various information such as battery voltage, current, power, power, number of cycles, single cell voltage, cell voltage balance, etc. to help you understand its operation status through our software platform at the maintenance center.

Envrionment Management

The deployment environment of Edge Span U1000 LTEP CCTV backup power supply is relatively complex, so Edge Span has built-in temperature and humidity sensors that can synchronize real-time conditions to the software platform.

POE Switch Management and Control

As a POE UPS, Edge Span U1000 LTEP has very comprehensive POE management function.The POE switch board embedded in the system will be managed by our software platform. The port status can be remotely managed through the software platform. The POE port can be remotely controlled to shut down and restart. Based on this function, the CCTV system can be restarted remotely to solve the camera freeze problem in most cases.

Third Party Software Platform Integration

Although Edgeware has its own software platform, customers often have their own considerations for the management of the entire network and have their own management system or OSS. Edge Span U1000 LTEP backup power supply is only part of customer network.Therefore, Edge Span can also provide services that are integrated into your third-party platform.

PRTG Software Platform

https://www.paessler.com/

Thingsboard Software Platform

https://thingsboard.io/

Customers have various ways of managing Edge Span U1000 LTEP, so we also provide MQTT and SNMP protocols to connect with customers’ software platforms.

MQTT Inteface Report

SNMP Interface Report

Customization Development

We know that the scenarios faced by Edge Span U1000 LTEP backup power supply are very diverse, and it is impossible for a fixed model to meet all needs. Edgeware is happy to provide customers with customized services so that our products can accurately meet customer scenarios and achieve one-stop deployment.

Specifications

Edge Span U1000 LTEP CCTV  Backup Power Supply General Specifications

Dimension

W*H*D 371mm*450mm*234mm  

Weight

24kg(with all system)

Material

Aluminum

Ingress Protection

IP65

Heat Dissipation

No fan design, natural heat dissipation

System Operating Temperature

-20~+75°C, 5%~90% RH Non condensing

DC-UPS

Rated Power 1000W

Input 110V/220V 50/60Hz Output 42.00-58.00VDC and AC110V or 220V( AC Voltage need to define based on customer’s country and region )

Battery

48V25AH Lithium Battery with BMS(1200Wh)

Surge Suppression

20KA

Protection

Remote control power on and off from Edgeware convergence platform

20A 110v/220v

Leakage Protection

Overvoltage Protection

Under Voltage Protection

Overcurrent Protection

Short circuit Protection

Lightning Protection

Network Module:

Industrial Layer 2 POE Switch 

GE Downlink: 8*10/100/1000M Base-T ports

GE Uplink : 2*10/100/1000M Base-X or Base T ports

Industrial Layer 3 Router 

GE Downlink: 4*10/100/1000M Base-T ports

GE Uplink : 1*10/100/1000M Base-X or Base T ports

PoE:

6*POE/POE+ Ports with 30W max power per port

2*POE++ Ports with 110W max power per port  

Total power should not be bigger 400W

Output Power

DC12V DC48 can be customized based on requirement

Output and Input Signal

External Sensor Integration can be customized based on requirement

System Monitoring and Management

Work with Edgeware Convergence software platform to perform system monitoring and management

Environment Monitoring

System temperature, humidity.

UPS Status Monitoring

Input Voltage, Output Voltage

Input/Output Power,Rated Power

Battery Charge/Discharge Current

Input Current, Load Current

Normal, Power Grid Off, Fault

AC Power Input Monitoring

Remote Control

Failure Status

Voltage

Current

Undervoltage

Overvoltage

Overcurrent

Current leakage

Battery Status Monitoring

Battery voltage , current, remaining capacity, temperature

Battery working status, battery charge and discharge current

Battery health estimation( Battery life time estimation )

External Light Control

External light controlt

Typical Application Scenario

cctv cabinet,solar cabinet, solar termination cabinet, Solar Controller enclosure, video surveillance cabinet, IoT Cabinet, IoT device enclosure, IoT enclosures

Smart City, Industrial Control, video surveillance, Telecom

Layer2 POE Switch Specification

 

Network Module Switching Capacity

128Gbps

MAC

8K

Network Module Protocol Supported

4K VLAN based on port, IEEE802.1q VLAN based on the protocol, VLAN based on MAC QinQ configuration, Port configuration of Access, Trunk, Hybrid

LACP, Static aggregation, Max 3 aggregation groups and 8 ports per group.

STP (IEEE802.1d),RSTP (IEEE802.1w),MSTP (IEEE802.1s)

MLD Snooping v1/v2,Multicast VLAN IGMP Snooping v1/v2, Max 1024 multicast groups, Fast log out

Bidirectional data mirroring based on port

Flow-based Rate Limiting Flow-based Packet Filtering 8*Output queues of each port 802.1p/DSCP priority mapping Diff-Serv QoS,Priority Mark/Remark Queue Scheduling Algorithm (SP, WRR,)

Port-based Issuing ACL,ACL based on port and VLAN L2 to L4 packet filtering, matching first 80 bytes message. Provide ACL based on MAC, Destination MAC address, IP Source, Destination IP, IP Protocol Type, TCP/UDP Port, TCP/UDP Port Range, and VLAN, etc

IP-MAC-VLAN-Port binding ARP inspection,Anti-DoS attack AAA & RADIUS,MAC learning limit Mac black holes,IP source protection IEEE802.1X & MAC address authentication Broadcast storm control,Backup for host datum

SSH 2.0,SSL,Port isolation,ARP message speed limit User hierarchical management and password protection

DHCP Client,DHCP Snooping,DHCP Server,DHCP Relay

 

Layer3 Router Module Embedded Specifications

MOBILE

Status

Signal strength (RSSI), SINR, RSRP, RSRQ, EC/IO, RSCP, Bytes sent/received, connected band, IMSI, ICCID

SMS

SMS status, SMS configuration,

Black/White list

Operator black/white list

Band management

Band lock, Used band status display

APN

Auto APN

Bridge

Direct connection (bridge) between mobile ISP and device on LAN

Passthrough

Router assigns its mobile WAN IP address to another device on LAN

Dual PDN

Possibility to use different PDNs for dual network access and services (not available in standard FW)

 

 

NETWORK

Network protocols

TCP, UDP, IPv4, IPv6, ICMP, NTP, DNS, HTTP, HTTPS, FTP, SMTP, SSL v3, TLS, ARP, VRRP, PPP, PPPoE, UPnP, SSH, DHCP, Telnet client, SNMP

Connection monitoring

TCP-Ping Reboot, Periodic Reboot, LCP and ICMP for link inspection

Firewall

Port forward, traffic rules, custom rules

DHCP

Static and dynamic IP allocation, DHCP Relay

QoS

Speed control of physical interface: WAN, LAN, Modem

DDNS

7 service providers, others can be configured manually

Network backup

VRRP, Mobile, Wired and each of which can be used as backup, using automatic Failover

 

 

 

 

SECURITY

Authentication

Pre-shared key, digital certificates, X.509 certificates

Firewall

Pre-configured firewall rules can be enabled via WebUI, unlimited firewall configuration via CLI; DMZ; NAT; NAT-T

Attack prevention

DDOS prevention (SYN flood protection, SSH attack prevention, HTTP/HTTPS attack prevention), port scan prevention (SYN-FIN, SYN-RST, NULL flags, FIN scan attacks)

VLAN

Port and tag based VLAN separation

Mobile quota control

Set up custom data limits for the SIM card

WEB filter

Blacklist for blocking out unwanted websites, whitelist for specifying allowed sites only

Access control

Flexible access control of TCP, UDP, ICMP packets, MAC address filter.

 

OpenVPN

Multiple clients and server can be running simultaneously, 12 encryption methods

OpenVPN Encryption

DES-CBC, RC2-CBC, DES-EDE-CBC, DES-EDE3-CBC, DESX-CBC, BF-CBC, RC2-40-CBC, CAST5-CBC, RC2-64-CBC, AES-128-CBC, AES-192-CBC, AES-256-CBC

IPsec

IKEv1, IKEv2, supports up to 4 x VPN IPsec tunnels (instances), with 5 encryption methods (DES, 3DES, AES128, AES192, AES256)

GRE

GRE tunnel

PPTP, L2TP

Client/Server services can run simultaneously

 

MONITORING & MANAGEMENT

WEB UI

HTTP/HTTPS, status, configuration, FW update, CLI ,troubleshoot, event log, system log, kernel log

SSH

SSH (v1, v2)

SMS

SMS status, SMS configuration, send/read SMS via HTTP POST/GET

SNMP

SNMP (v1, v2, v3), SNMP trap

×