CCTV UPS Edge Span U60 LSP-4

Layer 2 Industrial POE Switch, 300W Industrial UPS and Battery All in One CCTV UPS

What is CCTV UPS

CCTV UPS is an uninterruptible power supply designed specifically for video surveillance camera scenarios. Unlike general UPS, CCTV UPS is often deployed in outdoor environments, and the power 300W is sufficient to meet the working needs of battery backup for camera system. The general UPS on the market is usually suitable for indoor environments, and the power is 1KVA or even higher, which is unnecessary for CCTV camera scenarios,also increase heat dissipation and make system more complex. For CCTV UPS scenarios, we have developed the Edge Span U60 LSP-4 series of CCTV UPS specifically for scenarios with 4 or fewer cameras. In order to meet the needs of outdoor use, CCTV UPS should be completely waterproof and have a protection level of IP65 or above. In addition, as the main means of powering CCTV cameras, it should provide POE+ (802.3at max 30W) and POE++ (802.3bt max 110W). In addition, its CCTV UPS itself should be used as a layer 2 aggregation node to provide complete layer 2 switching functions. Finally, CCTV UPS should be deployed as a whole device, with integrated monitoring and management. No more traditional outdoor cabinet assembly and integration method.

Contact Us

Features of CCTV UPS

IP65/NEMA4X Level Protection

CCTV UPS should have IP65/NEMA4X level protection. CCTV cameras are deployed in very complex environments, usually outdoors. Humidity, high-salinity air, and other conditions have a significant impact on the stability of the equipment. Most CCTV cameras are designed with IP65 or higher ingress protection. Therefore, as a power supply for CCTV cameras, it must have IP65 or higher protection capabilities to ensure the stability of the entire CCTV solution.

Impact-Resistant Housing Design

The design of CCTV UPS housing must take into account how to ensure that the entire system will not be easily damaged by external influences when it is deployed outdoors all year round. Therefore, impact-resistant housing with rugged system design is necessary. Our products have an overall IK08 protection level.

No risk of rust

When a CCTV UPS is deployed outdoors for 5-10 years, it will face the risk of rusting even if it uses rust-proof steel materials such as 304 stainless steel, not to mention materials such as galvanized steel. When CCTV UPS is deployed at the seaside, border forests, etc., the challenge is even greater. Therefore, in terms of design, we believe that the entire system must be completely rust-proof. The CCTV UPS designed by Edgeware uses a one-time cast aluminum shell, and the material determines that it has no risk of rusting.

Lightning protection and Grounding

When CCTV UPS is installed in an outdoor environment, it will be threatened by lightning. Lightning can have a fatal impact on key components of the equipment, such as induction lightning damage or surge. Therefore, CCTV UPS must have a good lightning protection design. At the same time, we strive to give customers guidance on grounding so that the entire system is properly grounded. Poor grounding will render all good lightning protection designs ineffective.

Natural Heat Dissipation

Natural heat dissipation is very important for CCTV UPS. Because most UPS for CCTV camera systems are deployed outdoors, and the maintenance cost of outdoor environment is very high. UPS systems based on FAN cooling are mechanical parts, which are easy to be damaged, resulting in high maintenance costs at the site. Outdoor UPS systems based on Natural heat dissipation can be maintenance-free for a long time, thus greatly reducing the maintenance cost at the site and saving OPEX.

Lithium Battery with High Temperature Tolerance and High Power Density

General UPS uses lead-acid batteries and AGM batteries. These types of batteries are not suitable for outdoor use. Because the outdoor ambient temperature is much higher than the operating temperature of these types of batteries, and the lead-acid battery is large in size, which will inevitably increase the size of the entire system. Outdoors, if a CCTV UPS is too large, it will greatly increase the installation and transportation costs. Therefore, we insist on using high temperature resistant, high capacity density lithium batteries.

POE+/POE++

POE+ (802.3at) and POE++ (802.3bt) are commonly used to power video surveillance cameras. Now more and more PTZ cameras on the market require higher power supplies such as 110W. Therefore, as a CCTV UPS, it is necessary to provide stable POE+/POE++ functions, and POE++ should meet the latest PTZ requirements to reach 110W.

 

Monitoring and Management from Software Platform

CCTV UPS is the core component of CCTV network. The operation status of its battery, UPS and POE switch should be remotely monitored and managed by the software platform. Edgeware has designed complete monitoring and management in CCTV UPS. We have our own software platform Convergence V2 software platform. We can also report the monitoring and management information to the customer’s third-party software platform.

Edge Span U60 LSP-4 CCTV UPS

  • Industrial level 300W UPS 
  • Industrial level manageable layer 2 POE Switch(4 ports downlink with 2ports 802.3bt 110W, 2 ports 802.3at 30W, 1 ports uplink can be configured 1000Base-x or 1000Base-T)
  • Lithium battery 10AH as (48V)with 480Wh power as battery backup for camera system can support the whole system to run for 2 hours – 4 hours without power grid(Also ahve 5AH(48V) 240Wh version for cost down request )
  • IP65/NEMA4X ingress protection,dust and water penetration-free system
  • Configured with comprehensive system monitoring for in enclosure environment, AC input voltage current power, battery management, UPS management, POE switch management.
  • 20Ka surge protection

Dimension and Weight

CCTV UPS Edge Span U60 LSP-4 is designed to be as small and light as possible without any problems in terms of protection and heat dissipation, making it easier and more convenient to deploy and install outdoors.The weight and diameter of the equipment are as follows:

  • The weight of the whole system is 12.5kg (with battery installed)
  • Dimension of the whole system: 351mm*295.5mm*150mm (W*H*D)

Installation of CCTV UPS

CCTV UPS with Pole Mounting Installation

CCTV UPS can be equipped with pole mounting accessories so that the entire system supports pole mounting installation

CCTV UPS with Wall Mounting Installation

CCTV UPS can be equipped with wall mounting accessories so that the entire system supports wall mounting installation

Application of CCTV UPS

Video Surveillance Site

CCTV UPS Edge Span U60-LSP-4 is mainly designed for 1-4 cameras. It provides POE+/POE++ power for the camera and also acts as an access switch for the entire network to aggregate the traffic of CCTV Camera edge site. If you need a model with more than 4 ports, please refer to Edge Span U60 LSP-7.

WIFI Acess Point Site

CCTV UPS Edge Span U60 LSP-4 can also be used for access to WIFI AP sites.

Weather Sensor Site

CCTV UPS Edge Span U60 UPS can provide energy and backhaul for smart city sensor sites. If customers need to add special requirements such as DC12V, DC24V, RS485 interface, etc., we can customize it according to the scenario.

Wireless Microwave Site

CCTV UPS Edge Span U60 camera can provide power backup and traffic aggregation for wireless microwave sites.

Port Configuration

As shown in the figure above, the port configuration of Edge Span U60 LSP-4 CCTV UPS. There are 4 LAN Port 1000Base-T, of which two ports support 802.3bt 110W and two ports support 802.3at 30W. In addition, the uplink port is generally configured as 1*1000Base-X SFP ports, but it can also be configured as 1*1000 Base-T ports according to customer needs.

If the customer needs to add POE to the uplink port, it can be customized according to the customer’s needs. We found that there are many scenarios where customers need to add passive POE to the uplink port to match the POE standard requirements of the uplink microwave.

If you need 7 Lan Port POE version, we also have the corresponding model, please refer to the following link:

Edge Span U60 LSP-7

If you need 8 ports please refer the following links :

Edge Span U60 LSP-8

The system is also equipped with a battery turn off button and a system operation status light. These control components are all waterproof design devices.

Main Function Units

As shown in the figure above, this is the configuration of CCTV UPS Edge Span LSP-4.

UPS Remote Monitoring and Management

CCTV UPS Edge Span U60 LSP-4 included one Edge Control unit, through it UPS can report input voltage, input current, operating power, UPS temperature, PFC voltage, output voltage, output current, battery voltage, battery current, output power and other important operating parameters to software platform, so that customers can monitor UPS operation in real time and view historical operating status.

Battery Management System

As battery backup for camera system,the operating status of the battery is very important for CCTV UPS, so our batteries are equipped with a built-in Battery Management System that can report the battery voltage, current, power, power, number of cycles, single cell voltage, cell voltage balance, etc. to the software platform, so that customers can remotely know the battery operating status.

Envrionment Management

CCTV UPS Edge Span has built-in temperature and humidity sensors that can synchronize real-time conditions to the software platform.

POE Switch Management and Control

The POE switch board embedded in the system will be managed by our software platform. The port status can be remotely managed through the software platform. The POE port can be remotely controlled to shut down and restart. Based on this function, the CCTV camera can be restarted remotely to solve the camera freeze problem in most cases.

Third Party Software Platform Integration

Although Edgeware has its own software platform, customers often have their own considerations for the management of the entire network and have their own management system or OSS. CCTV UPS is only part of customer network.Therefore, Edge Span can also provide services that are integrated into your third-party platform.

PRTG Software Platform

https://www.paessler.com/

Thingsboard Software Platform

https://thingsboard.io/

Customers have various ways of managing UPS for CCTV cameras, so we also provide MQTT and SNMP protocols to connect with customers’ software platforms.

MQTT Inteface Report

SNMP Interface Report

Customization Development

We also provide customers with customized development based on CCTV UPS Edge Span U60 LSP-4, which includes the following services:
(1) Embed the customer’s equipment in Edge Span U60 enclosure, such as replacing the POE switch board with the customer’s POE switch
(2) Increase or decrease the battery capacity
(3) Customize the control logic of the whole machine. For example:
A. When the battery capacity is less than 40%, close several specific POE ports to put the whole machine into power saving mode.
Read a specific sensor, set an alarm, and turn on a certain device.
B. The above are just simple examples, because our company has customized and developed many projects and it is impossible to list them one by one. In short, we are very willing to carry out customized development based on customer scenarios to achieve one-stop delivery.

Specifications

Edge Span U60 LSP-4 All in One CCTV UPS Specifications

Dimension

W*H*D 295mm*355mm*150mm

Weight

12.5kg(with all system)

Material

Aluminum

Ingress Protection

IP65

Heat Dissipation

No fan design, natural heat dissipation

System Operating Temperature

-20~+75°C, 5%~90% RH Non condensing

DC-UPS

Rated Power 300W

Input 110V/220V 50/60Hz Output 42.00-58.00VDC

Battery

48V5AH Lithium Battery with BMS(Can be configured as 10AH if customer requested)

Surge Suppression

20KA

Protection

Remote control power on and off from Edgeware convergence platform

10A 110v/220v

Leakage Protection

Overvoltage Protection

Under Voltage Protection

Overcurrent Protection

Short circuit Protection

Lightning Protection

Network Module:

GE Downlink: 4*10/100/1000M Base-T ports

GE Uplink : 1 *10/100/1000M Base-X or Base T port

Layer 2 POE switch module manageable

PoE:

2*POE+ 802.3at with 30W per port 

2*POE++ 802.3bt with 110W per port

Total power should not be bigger 250W

Output Power

DC12V DC48 can be customized based on requirement

Output and Input Signal

External Sensor Integration can be customized based on requirement

System Monitoring and Management

Work with Edgeware Convergence software platform to perform system monitoring and management

Environment Monitoring

System temperature, humidity.

Box open and close status

UPS Status Monitoring

Input Voltage, Output Voltage

Input/Output Power,Rated Power

Battery Charge/Discharge Current

Input Current, Load Current

Normal, Power Grid Off, Fault

AC Power Input Monitoring

Remote Control

Failure Status

Voltage

Current

Undervoltage

Overvoltage

Overcurrent

Current leakage

Battery Status Monitoring

Battery voltage , current, remaining capacity, temperature

Battery working status, battery charge and discharge current

Battery health estimation( Battery life time estimation )

External Light Control

External light controlt

Typical Application Scenario

cctv cabinet,solar cabinet, solar termination cabinet, Solar Controller enclosure, video surveillance cabinet, IoT Cabinet, IoT device enclosure, IoT enclosures

Smart City, Industrial Control, video surveillance, Telecom

Network Module Switching Capacity

128Gbps

MAC

8K

Network Module Protocol Supported

4K VLAN based on port, IEEE802.1q VLAN based on the protocol, VLAN based on MAC QinQ configuration, Port configuration of Access, Trunk, Hybrid

LACP, Static aggregation, Max 3 aggregation groups and 8 ports per group.

STP (IEEE802.1d),RSTP (IEEE802.1w),MSTP (IEEE802.1s)

MLD Snooping v1/v2,Multicast VLAN IGMP Snooping v1/v2, Max 1024 multicast groups, Fast log out

Bidirectional data mirroring based on port

Flow-based Rate Limiting Flow-based Packet Filtering 8*Output queues of each port 802.1p/DSCP priority mapping Diff-Serv QoS,Priority Mark/Remark Queue Scheduling Algorithm (SP, WRR,)

Port-based Issuing ACL,ACL based on port and VLAN L2 to L4 packet filtering, matching first 80 bytes message. Provide ACL based on MAC, Destination MAC address, IP Source, Destination IP, IP Protocol Type, TCP/UDP Port, TCP/UDP Port Range, and VLAN, etc

IP-MAC-VLAN-Port binding ARP inspection,Anti-DoS attack AAA & RADIUS,MAC learning limit Mac black holes,IP source protection IEEE802.1X & MAC address authentication Broadcast storm control,Backup for host datum

SSH 2.0,SSL,Port isolation,ARP message speed limit User hierarchical management and password protection

DHCP Client,DHCP Snooping,DHCP Server,DHCP Relay

×